Aegean Labs

LaboratoryThessaloniki, Greece

7.3/ 1022 of 30 pts
PAL Testing Evidence Score

Ranked on the Greece page. Based on what the company publishes; not an audit.

Facility transparency
5/6
Analytical scope
7/9
Quality & reporting
5/10
Ordering transparency
5/5

Overview

Aegean Labs is a peptide analytical testing business based in Thessaloniki, Greece. The site states it performs HPLC-based purity and identity testing, LC-MS/MS analysis, and LAL-based endotoxin testing, describing its laboratory as ISO 17025-aligned rather than stating formal accreditation. Published services include purity and identity testing, sterility screening, and endotoxin count, with listed prices ranging from $250 to $700. The site states standard turnaround is 12-16 days, though it currently notes delays due to demand and has paused accepting new sample submissions. A public verification portal allows lookup of report IDs, and a sample report is published for viewing. Contact is provided via an email address and a Thessaloniki street address. Details are summarised from the company's own website and have not been independently audited.

Key facts

Business typeLaboratoryPerforms the analyses in its own laboratory.
Websiteaegean-labs.com
Public contactinfo@aegean-labs.com · Contact page
Sample submission / quoteSample submission form source
AccreditationISO 17025-aligned quality systems (not counted: no accreditor/certificate, or not yet granted) source
PricingPurity & Identity: $350 source
Sterility: $250 source
Endotoxin Count: $250 source
Full Panel (purity & identity, sterility, endotoxin count): $700 source
Turnaround12-16 days standard testing turnaround source
Report verificationPublic lookup available source
Sample reportPublished source

Confirmed locations

  • Testing facility Agias Sofias 106, Thessaloniki, Greece source

Testing services

ServiceMethod (as published)Source
Purity (HPLC/UPLC)HPLC AnalysisHPLC with UV detection at 214nmsource
IdentityMass SpectrometryLC-MS/MSsource
Quantity / net contentMeasured Content / QuantitationHPLC quantitationsource
EndotoxinEndotoxin TestingLAL assaysource
Rapid microbial / PCR screenSterilityunspecified sterility screeningsource

A rapid / PCR microbial screen is not a compendial culture-based sterility test (e.g. USP <71>).

Evaluation criteria

PAL Testing Evidence Score v1. How it works. – means not found in public sources as of 2026-09-30; it is not a finding that the facility lacks it.

Facility transparency 5/6

  • ✓
    Street address published 2 ptsDocumented. A street address (not a PO box, registered agent or mailing address) is published on the company's own site.
  • ✓
    Address identified as the testing facility or sample intake 2 ptsDocumented. The site ties an address to the laboratory or to where samples are received.
  • –
    Legal entity named 1 ptNot found in public sources. The operating company's legal name is published.
  • ✓
    Named scientific staff 1 ptDocumented. At least one scientist or lab lead is named.

Analytical scope 7/9

  • ✓
    Purity testing (HPLC/UPLC) 2 ptsDocumented. Chromatographic purity testing is offered.
  • ✓
    Identity testing (method named) 2 ptsDocumented. Identity confirmation is offered and the method is named (e.g. LC-MS, MALDI-TOF). Mass spectrometry counts.
  • ✓
    Quantity / net content 2 ptsDocumented. Quantitation of the amount in the vial is offered.
  • ✓
    Endotoxin 1 ptDocumented. Bacterial endotoxin testing is offered.
  • –
    Culture-based sterility (e.g. USP <71>) 1 ptNot found in public sources. Compendial or culture-based sterility testing. PCR or rapid screens are listed but do not earn this point.
  • –
    Heavy metals / elemental 1 ptNot found in public sources. Heavy-metal or elemental analysis is offered.

Quality & reporting 5/10

  • ✓
    Method detail documented 2 ptsDocumented. The site documents how analyses are run (instrument, column, detector, reference standards or validation), not just a technique name.
  • –
    Accreditation stated with accreditor or certificate number 2 ptsNot found in public sources. An accreditation such as ISO/IEC 17025 is stated with the accrediting body or certificate number. 'Pending', 'aligned' or 'compliant' statements do not count.
  • –
    Accreditation found in the accreditor's public directory 3 ptsNot found in public sources. PAL found the accreditation in the accrediting body's public directory, or a verified owner submitted it and PAL confirmed it there.
  • ✓
    Public report verification lookup 2 ptsDocumented. Anyone can check a report's authenticity by ID or QR code.
  • ✓
    Sample report published 1 ptDocumented. An example report or COA can be viewed.

Ordering transparency 5/5

  • ✓
    Concrete pricing published 2 ptsDocumented. At least one concrete price is published.
  • ✓
    Turnaround time published 1 ptDocumented. A concrete turnaround time is published.
  • ✓
    Online ordering, submission or quote link 2 ptsDocumented. An online order, sample submission form or quote request is available.

Is this your facility?

Claiming is free. PAL first verifies that you are authorized to act for the business. Verified owners can then use three separate routes. Peptide Ad Lab never charges a business to correct a factual inaccuracy.

  • Company-provided updatesYour description, testing services, methods and instruments, facility locations, sample submission link, turnaround, pricing and contact details, shown in a section labelled “Provided by the company”. Not checked by PAL and not used in the score. Free: sent to PAL as correction requests. PAL Pro: published directly.
  • PAL-reviewed evidenceDocuments or links for a scoring criterion. PAL reviews them under the same rule used for every facility; only accepted evidence changes a finding. Any plan.
  • PAL-verified lab credentialsAccreditations such as ISO/IEC 17025. They count only after PAL finds them in the accreditor’s public directory. Any plan.

PAL Pro is an optional paid plan for company-provided updates, extra images and the PAL Pro badge. It never verifies a credential, accepts evidence, or changes a finding, score, eligibility or ranking position.

Ownership verification confirms that you control the business. It is separate from laboratory credentials and from PAL Pro, it is not an endorsement, and it does not change any finding or score.

Claim This Profile

Sources

Last reviewed 2026-09-30. All facts above were taken from these pages on the company’s website.

Peptide Ad Lab has not tested samples at or audited this facility. Information is summarised from public sources and may change. Businesses can claim this profile to request corrections.

Back to top